Nanjing,China
+86-13813931455(WhatsApp)

Tag: hr

HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.

Poultry Incinerators

Basic Info. Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Additional Info. Trademark:nanjing clover Origin:Clover Product Description Our company is interested to purchase waste incinerator. Please contact us price information and shipping and shipment detail.  Samuel  Managing director  The National Depatment of Health with 3 sets of 50Kg/Hr Medical Waste Incinerators. Since the tender closes…
Read more

30 Kgs Burn Rate Incinerator

Basic Info. Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Additional Info. Trademark:CLOVER Product Description YDC incinerator is newest layout for waste treatment, include health care waste, animal cremation and other solid waste. This gear quality structural for kinds of website, such as hospital, hospital waste incinerator manufacturer, hospital waste incinerator manufacturer china, hospital waste…
Read more

Capacidad máxima de residuos médicos del incinerador

Información básica. No. de modelo: fabricantes de incineradores de desechos médicos Mercados de exportación: Global Descripción del producto Nanjing Clover Medical Technology Co., Ltd. es un fabricante líder de incineradores de desechos en China. Somos fabricantes locales y uno de los mayores exportadores de China. El equipo técnico de incineración pirolítica es el principal tratamiento…
Read more

Incinerator Medical Waste Maximum Capacity

Basic Info.   Model NO.:medical waste incinerator manufacturers Export Markets:Global Product Description   Nanjing Clover Medical Technology Co., Ltd. is a leading waste incinerator manufacturer in China. Key Features:  * All versions with Dual combustion room.  * Stainless Steel chimney/stack, long life. *based on order  * High fever, long life of incinerator.  * Free or…
Read more

hot medical waste disposing machine, Operation Condition: 8-16 hr/ day

hot medical waste disposing machine, Operation Condition: 8-16 hr/ day  Control: Built-in data recording Operating temperature: Incinerator  /Primary Combustion Chamber Primary Chamber: 900 – 1200 0C Type: horizontal/vertical Temperature:  1200- 1300 oC Residence time of gases : >2 seconds Ash Residue: <5% of original waste size Ash Handling System: Both Automatic and manual removal of Ash. Must ensure removal/treatment of hazardous remnants of ash Flue gas treatment   system : Capable of treating the flow of flue  gas as the incinerator is operating at its maximum capacity Auxiliary device: Water level gauge, pressure sensor, PH sensor..etc  Auxiliary device: Fuel cut-off device Waste  feeding mechanism: Automatic pneumatic/hydraulic waste loading system or conveyor belt , capacity 650-800 L at a time                                                                                                                                       Chimney (Stack): Type: Vertical type height:>7 meter’ Material: Fireproof cast, stainless steel OUTPUT:  GAS- SMOKELESS,ODORLESS  ASH -Max <5% of original waste size Reduction of Pollutant gas SO2, HCL, HF and line particulate Emission standard: WHO/ European Test report for emission testing provided? Heat exchange mode: Automatic Type: Constant loading, Top LoadingCapacity/Burn Speed per hour: 250 -300 kg/hr Substance:External- 3 layers Internal lining:  a fire proof material of pre-fired refractory bricks Using Aluminium lining, resistant to corrosive Gas or Waste and Also to thermal shockSecondary Combustion Chamber:

hot medical waste disposing machine, Operation Condition: 8-16 hr/ day

hot medical waste disposing machine, Operation Condition: 8-16 hr/ day  Control: Built-in data recording Operating temperature: Incinerator  /Primary Combustion Chamber Primary Chamber: 900 – 1200 0C Type: horizontal/vertical Temperature:  1200- 1300 oC Residence time of gases : >2 seconds Ash Residue: <5% of original waste size Ash Handling System: Both Automatic and manual removal of Ash. Must ensure removal/treatment of hazardous remnants of ash Flue gas treatment   system : Capable of treating the flow of flue  gas as the incinerator is operating at its maximum capacity Auxiliary device: Water level gauge, pressure sensor, PH sensor..etc  Auxiliary device: Fuel cut-off device Waste  feeding mechanism: Automatic pneumatic/hydraulic waste loading system or conveyor belt , capacity 650-800 L at a time                                                                                                                                       Chimney (Stack): Type: Vertical type height:>7 meter’ Material: Fireproof cast, stainless steel OUTPUT:  GAS- SMOKELESS,ODORLESS  ASH -Max <5% of original waste size Reduction of Pollutant gas SO2, HCL, HF and line particulate Emission standard: WHO/ European Test report for emission testing provided? Heat exchange mode: Automatic Type: Constant loading, Top LoadingCapacity/Burn rate per hour: 250 -300 kg/hr Substance:External- 3 layers Internal Liner:  a fire proof material of pre-fired refractory bricks Using Aluminium Liner resistant to corrosive Gas or Waste and Also to thermal shockSecondary Combustion Chamber:

Incinerador diesel alimentado 150kg / hr

INCINERADOR, DIESEL. CAPACIDADE: Queimador 150 kg / hr. Quantidade: Dois [2] com acessórios completos. Tipos de resíduos usados: RESÍDUOS GERAIS As máquinas serão certificadas para operação pela PME após passar nas investigações do local. Os detalhes técnicos com os quais nos preocupamos são: – Capacidade (capacidade de queima de resíduos por hora). 150kg / hora.…
Read more

Design standard Multiple chamber incinerator

Waste type organics domestical  waste Calorific value of waste 9,25 MJ/kg Ash content 20.80 % Density 291 Kg/m3 Waste quantity (kg per hr) 12,500 Total Heat input (Gcal/hr) 23.71 organics domestical  waste Solid Domestic waste, after separating the recyclable, such as: plastic, cloth, metal, paper, wood, glass, stones, etc. than larger 10 cms Design standard Multiple chamber incinerator to the design of EPA  standards, Air pollution control Description of the Chimney Top mounted, self supporting Incinerator performance 150kg/hr Refuse  Hospital waste and carcasses Recommended Temperatures Minimum 1000⁰C Dimensions: Length  Width  Height  Extra width for burners At least 3000mm Loading door opening Minimum 700mm x 600mm Hearth area 5.00square meters Description or grate/hearth A full hearth supplied to prevent contaminated liquids from flowing into the ash pit without being incinerated Primary chamber volume At least 3 cubic meters Mixing chamber volume At least 1 cubic meters Settling chamber volume At least 3 cubic meters Weight excluding chimney 15, 000kg at manufacture Firing tools supplied Hoe, Poker and rake

Design standard Multiple chamber incinerator

Waste type organics domestical  waste Calorific value of waste 9,25 MJ/kg Ash content 20.80 % Density 291 Kg/m3 Waste quantity (kg per hr) 12,500 Total Heat input (Gcal/hr) 23.71 organics domestical  waste Solid Domestic waste, after separating the recyclable, such as: plastic, cloth, metal, paper, wood, glass, stones, etc. than larger 10 cms Design standard Multiple chamber incinerator to the design of EPA  standards, Air pollution control Description of the Chimney Top mounted, self supporting Incinerator performance 150kg/hr Refuse  Hospital waste and carcasses Recommended Temperatures Minimum 1000⁰C Dimensions: Length  Width  Height  Extra width for burners At least 3000mm Loading door opening Minimum 700mm x 600mm Hearth area 5.00square meters Description or grate/hearth A full hearth supplied to prevent contaminated liquids from flowing into the ash pit without being incinerated Primary chamber volume At least 3 cubic meters Mixing chamber volume At least 1 cubic meters Settling chamber volume At least 3 cubic meters Weight excluding chimney 15, 000kg at manufacture Firing tools supplied Hoe, Poker and rake

Incinerator Rated Capacity: 100/KG/Hr

Incinerator Rated Capacity: 100/KG/Hr Type of Design: Double Chambered Mode of Heating: Heating Elements  Primary Combustion Chamber  Waste Charging Door: Provided with refractory lining with sealing gaskets  Ash Removed Door: Provided with refractory lining with sealing gaskets  Outer Body MOC: Mild Steel, 5mm  Primary Chamber: Stainless Steel  Operating Temperature :800. ± 50◦C  Insulation: Insulation Brick  Heating Elements Type: Kanthal Al Grade Power Consumption: 75 KW ( Initial Load )  Electrical Supply :3 Phase 440 Volt  Control Panel  MOC: Mild Steel Power Coated No. of Temp: Controllers : 2 Nos  Details: The Control Panel will be provided with contract as relays , switches , indicators etc . Operative on 3 phase. I.D.Fan Type: Centrifugal Type  MOC: Mild Steel  Capacity:2 HP/3Phase  Make of Motor: Kirloskar /Havells/Crompton Combustion Air Fan Type: Centrifugal Type  Capacity: 1HP/3Phase  Make of Motor: Kirloskar /Havells/Crompton Stack: Type:  Wire Supported  MOC:  Mild Steel of ISstd Height :3 Meters or more