Nanjing,China
+86-13813931455(WhatsApp)

Design standard Multiple chamber incinerator

HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.

Design standard Multiple chamber incinerator

Waste type organics domestical  waste
Calorific value of waste 9,25 MJ/kg
Ash content 20.80 %
Density 291 Kg/m3
Waste quantity (kg per hr) 12,500
Total Heat input (Gcal/hr) 23.71
organics domestical  waste Solid Domestic waste, after separating the recyclable, such as: plastic, cloth, metal, paper, wood, glass, stones, etc. than larger 10 cms
Design standard Multiple chamber incinerator to the design of EPA  standards, Air pollution control
Description of the Chimney Top mounted, self supporting
Incinerator performance 150kg/hr
Refuse  Hospital waste and carcasses
Recommended Temperatures Minimum 1000⁰C
Dimensions:
Length 
Width 
Height 
Extra width for burners At least 3000mm
Loading door opening Minimum 700mm x 600mm
Hearth area 5.00square meters
Description or grate/hearth A full hearth supplied to prevent contaminated liquids from flowing into the ash pit without being incinerated
Primary chamber volume At least 3 cubic meters
Mixing chamber volume At least 1 cubic meters
Settling chamber volume At least 3 cubic meters
Weight excluding chimney 15, 000kg at manufacture
Firing tools supplied Hoe, Poker and rake