HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.

Incinérateur PLC (TS50 PLC)

Informations de base. N ° de Modèle: TS50 PLC Sources de pullution: traitement des déchets solides Méthodes de traitement: combustion Marchés d’exportation: mondiaux Information additionnelle. Marque Déposée: Clover Emballage: conteneur plein Standard: 50 kg par heure Origine: Chine Capacité de production: 1500 unités / an Description du produit Nanjing Clover Medical Technology Co., Ltd. est…
Read more

50-100-150-200 Kgs per Hour Solid Waste Incinerator Model TS150 PLC 1570Liters Chamber

Waste Incinerator Model TS150 PLC, Overview This model is small-scale waste incineration equipment for small waste output.  Construction is dual/double combustion chamber with 02 sets oil burner, batch load  incineration equipment. Waste feed chamber is 1570Liters (1.57m3, TS150 PLC).  Primary & Secondary combustion chambers and smoke filter chamber.  Batch load on the bottom of chamber.…
Read more

medical incinerator

medical incinerator is incineration equipment for the waste from hospital, clinic,laboratory or other related department. the medical waste including plastic material like syringe, Infusion set, medical tube and medical dressing, clothes, and also surgical waste inclding human body part, etc. this kind of incineration equipment use oil(diesel oil) or gas(natural gas or lpg) to burn…
Read more

Controlled air medical waste incinerator designed for incineration of bio-medical waste

Controlled air medical waste incinerator designed for incineration of bio-medical waste generated at a blood-processing center. The waste to be treated mainly includes bio-waste (i.e. bodily fluids), infectious and hazardous waste such as syringes, needles, and other medical waste (i.e. silicon rubbers, plastic, textiles, papers, packs, etc.) Operational Specs Physical Specs Combustion Chamber Volume (m3) 8.80m3 Burn Rate* up to 1,500kg per hour Average Fuel Consumption 65 kg per hour or more (7 diesel burners) Operational Temperature 850 – 1320°C Gas Retention in Secondary Chamber Large secondary chamber     Temperature Monitoring Yes     Average ash residue (%) 3%     Thermostatic Device Yes   1000l diesel flue tank Venture gas scrubber Hydraulic Ram Feeding System Diesel Powered Large Incinerator Minimum Specification Required Standards1) Bidder or Brand ISO 9001 Certified2) Respecting international emission standardsElectrical characteristics3) A 230V, 60Hz single-phase electrical source.4) Protections against over-voltage and over-current line Requirements.5) Compliance with applicable Ghanaian standards and regulations.Operational characteristics6) Two-stage incineration with dual chamber combustion7) Burn rate: 15 – 20 Kg/h8) Ability: not less than 130 L9) Concentrations of most pollutants in stack gases under detection limits10) Diesel fuel11) Electronic Machine control12) Easy to operate and minimal training13) Any accessory or dedicated Apparatus necessary to the proper functioning and utilization of the equipment included

pet incinerator for sale

pet incinerator for sale: The pet cremation equipment humanized design with movable platform, small space covers for modern pet cremation business owner all over the world. ※Main Feature: — Double or Three Combustion Chamber — Double Italy Burner –Burning Rate: 18-120kgs per hour or more –Combustion Chamber: 0.4M3-1.5M3 or more ※Optional Function/Parts/Material/Burning Rate: — Movable…
Read more

large animal incinerators

Animal diseases, new virus strains and spread of infectious diseases are only few of the consequences of improper animal waste treatment. Incineration is the way forward for Bio-secure waste disposal. large animal incinerators is recognized as a most efficient solution for significant risk reduction in animal waste management. ※Main Feature: — Three Combustion Chamber —…
Read more

Controlled air medical waste incinerator designed for incineration of bio-medical waste

Controlled air medical waste incinerator designed for incineration of bio-medical waste generated at a blood-processing center. The waste to be treated mainly includes bio-waste (i.e. bodily fluids), infectious and hazardous waste such as syringes, needles, and other medical waste (i.e. silicon rubbers, plastic, textiles, papers, packs, etc.) Operational Specs Physical Specs Combustion Chamber Volume (m3) 8.80m3 Burn Rate* up to 1,500kg per hour Average Fuel Consumption 65 kg per hour or more (7 diesel burners) Operational Temperature 850 – 1320°C Gas Retention in Secondary Chamber Large secondary chamber     Temperature Monitoring Yes     Average ash residue (%) 3%     Thermostatic Device Yes   1000l diesel flue tank Venture gas scrubber Hydraulic Ram Feeding System Diesel Powered Large Incinerator Minimum Specification Required Standards1) Bidder or Brand ISO 9001 Certified2) Respecting international emission standardsElectrical characteristics3) A 230V, 60Hz single-phase Electric Supply.4) Protections against over-voltage and over-current line conditions.5) Compliance with applicable Ghanaian Criteria and regulations.Operational characteristics6) Two-stage incineration with Double chamber combustion7) Burn rate: 15 – 20 Kg/h8) Ability: less than 130 L9) Concentrations of most pollutants in stack gases below detection limits10) Diesel fuel11) Electronic system control12) Easy to operate and Nominal training13) Any Attachment or Committed device Required to the proper functioning and Usage of the equipment Comprised