Nanjing,China
+86-13813931455(WhatsApp)

Tag: hour

HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.

Solid Waste Incineration Big Scale

Basic Info. Model NO.:solid waste incinerator suppliers for the lab Export Markets:Global Product Description Nanjing Clover Medical Technology Co., Ltd.. Key Features:  * All models with Dual combustion chamber.  * Stainless Steel chimney/stack, long lifetime. *according to order  * High temperature, long lifetime of incinerator.  * Free or minimal installation onsite.  * High speed, from…
Read more

Animal Incinerator

Basic Info. Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Additional Info. Trademark:clover Product Description Key Features:  * All models with Dual combustion room.  * Stainless Steel chimney/stack, long lifetime. *based on sequence * High fever, long lifetime of incinerator.  * Free or minimal installation on site.  * High speed, from 10kgs to 500kgs per…
Read more

Animal Incinerator

Basic Info. Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Additional Info. Trademark:clover Product Description Key Features:  * All models with Dual combustion room.  * Stainless Steel chimney/stack, long lifetime. *based on sequence * High fever, long lifetime of incinerator.  * Free or minimal installation on site.  * High speed, from 10kgs to 500kgs per…
Read more

Pets Crematorium

Basic Info. Style:Crematorium Material:Crematorium Species:Dog Export Markets:Global Additional Info. Trademark:CLOVER Origin:Nanjing Clover Product Description The required circular Medical Waste Incinerator is going to be quoted according to Technical Specifications provided below:  1) A self-contained, gas gas, medical waste incinerator with a minimum burn speed capacity of 100 kg/day.  2) A medical waste incinerator shall be…
Read more

Pets Crematorium

Basic Info. Style:Crematorium Material:Crematorium Species:Dog Export Markets:Global Additional Info. Trademark:CLOVER Origin:Nanjing Clover Product Description The required circular Medical Waste Incinerator is going to be quoted according to Technical Specifications provided below:  1) A self-contained, gas gas, medical waste incinerator with a minimum burn speed capacity of 100 kg/day.  2) A medical waste incinerator shall be…
Read more

Medical Waste Incinerator Diesel and Gas Specification

Basic Info. Model NO.:medical solid waste incinerator 100kg Export Markets:Global Product Description Key Features:  * All versions with Dual combustion room.  * Stainless Steel chimney/stack, long life. *according to sequence * High fever, long life of incinerator.  * Free or minimum installation on site.  * High burn rate, from 10kgs to 500kgs per hour, up…
Read more

hiclover 10kgs per hour incinerator

Smallest waste incinerator for small hospital  average 10kgs per hour.  with double(2) sets burner. Equipment Technical Specifications Model YD-10 Feed Capacity Typical 20 kgs per feed Burning Rate Typical 10 kgs Each hour Burning Time Each Feed 2 hours Voltage 220V Fuel Diesel Petroleum Burner Italy Burner Feed Mode Manual Fuel consumption (Oil) 5.4-12.6 Kgs/Hour…
Read more

hiclover 10kgs per hour incinerator

Smallest waste incinerator for small hospital  average 10kgs per hour.  with double(2) sets burner. Equipment Technical Specifications Model YD-10 Feed Capacity Typical 20 kgs per feed Burning Rate Typical 10 kgs Each hour Burning Time Each Feed 2 hours Voltage 220V Fuel Diesel Petroleum Burner Italy Burner Feed Mode Manual Fuel consumption (Oil) 5.4-12.6 Kgs/Hour…
Read more

Incinerator Operating period Anticipated daily period 8 hours

Operating period Anticipated daily period 8 hours Maximum operating period 12hours Chamber Should be refractory lined to the following standards, hearth and lower section of chamber walls. Hot face materials Super dusty firebricks Limiting continuous service limit 1500°c Thickness 100mm Thermal conductivity 1.3W/mk Insulation Calcium silicate Limiting continuous service limit 1000°c Thickness 25mm Thermal conductivity 0.095w/mk Chimney/stack Should be manufactured from refractory lined mild steel or high quality air cooled stainless steel. The chimney/stack should have a minimum height of 10 meters above ground level Ignition burners Fully packed oil type complete with electric ignition and flame failure controls wired with continuous running fan and complete with all valves, fan and motor Maximum rating :               at least 450kw/hour Burner:                                  arranged for on/off operation Maximum consumption :   at least 6litres per hour Average consumption :      at least 3litres/hour After burner Fully packed oil type complete with electric ignition and flame failure controls wired with continuous running fan and complete with all valves fan and motor. Maximum rating :     At least 450kw/hour Burner:                        arranged for on/off operation Maximum consumption:     at least 9 litres/hour Average consumption:         at least 4.5 litres /hour Flue gas treatment Should have particulate remover (scrubbers) Electrical supply Single phase 220/240v a.c,50/60hz Documentation Operation manual   2 sets Service /maintenance manual 2 sets

Fenshaolu.com