Nanjing,China
+86-13813931455(WhatsApp)

Tag: hot

HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.

hot medical waste disposing machine, Operation Condition: 8-16 hr/ day

hot medical waste disposing machine, Operation Condition: 8-16 hr/ day  Control: Built-in data recording Operating temperature: Incinerator  /Primary Combustion Chamber Primary Chamber: 900 – 1200 0C Type: horizontal/vertical Temperature:  1200- 1300 oC Residence time of gases : >2 seconds Ash Residue: <5% of original waste size Ash Handling System: Both Automatic and manual removal of Ash. Must ensure removal/treatment of hazardous remnants of ash Flue gas treatment   system : Capable of treating the flow of flue  gas as the incinerator is operating at its maximum capacity Auxiliary device: Water level gauge, pressure sensor, PH sensor..etc  Auxiliary device: Fuel cut-off device Waste  feeding mechanism: Automatic pneumatic/hydraulic waste loading system or conveyor belt , capacity 650-800 L at a time                                                                                                                                       Chimney (Stack): Type: Vertical type height:>7 meter’ Material: Fireproof cast, stainless steel OUTPUT:  GAS- SMOKELESS,ODORLESS  ASH -Max <5% of original waste size Reduction of Pollutant gas SO2, HCL, HF and line particulate Emission standard: WHO/ European Test report for emission testing provided? Heat exchange mode: Automatic Type: Constant loading, Top LoadingCapacity/Burn Speed per hour: 250 -300 kg/hr Substance:External- 3 layers Internal lining:  a fire proof material of pre-fired refractory bricks Using Aluminium lining, resistant to corrosive Gas or Waste and Also to thermal shockSecondary Combustion Chamber:

hot medical waste disposing machine, Operation Condition: 8-16 hr/ day

hot medical waste disposing machine, Operation Condition: 8-16 hr/ day  Control: Built-in data recording Operating temperature: Incinerator  /Primary Combustion Chamber Primary Chamber: 900 – 1200 0C Type: horizontal/vertical Temperature:  1200- 1300 oC Residence time of gases : >2 seconds Ash Residue: <5% of original waste size Ash Handling System: Both Automatic and manual removal of Ash. Must ensure removal/treatment of hazardous remnants of ash Flue gas treatment   system : Capable of treating the flow of flue  gas as the incinerator is operating at its maximum capacity Auxiliary device: Water level gauge, pressure sensor, PH sensor..etc  Auxiliary device: Fuel cut-off device Waste  feeding mechanism: Automatic pneumatic/hydraulic waste loading system or conveyor belt , capacity 650-800 L at a time                                                                                                                                       Chimney (Stack): Type: Vertical type height:>7 meter’ Material: Fireproof cast, stainless steel OUTPUT:  GAS- SMOKELESS,ODORLESS  ASH -Max <5% of original waste size Reduction of Pollutant gas SO2, HCL, HF and line particulate Emission standard: WHO/ European Test report for emission testing provided? Heat exchange mode: Automatic Type: Constant loading, Top LoadingCapacity/Burn rate per hour: 250 -300 kg/hr Substance:External- 3 layers Internal Liner:  a fire proof material of pre-fired refractory bricks Using Aluminium Liner resistant to corrosive Gas or Waste and Also to thermal shockSecondary Combustion Chamber:

Mobile Diesel Fired Incinerator in container

Mobile Diesel Fired  Incinerator in container,  supplied with the following specifications: complete with constant ventilation fans for extraction,  factory installed inside one 20ft ISO container complete with lighting, ventilation fan, fire security, 3 access doors, and a 1200 litre fuel tank complete with a piping.  Fully containerised mobile  waste management solution for medical, animal, and industrial waste applications. Installed in Container (ISO) : 20” or its nearest equivalent model “ Tender Technical Specification Destruction rate of 50kg/hr Hot Hearth Principle Refractory insulation: a. Silicon carbide floor b. Minimum 22mm insulation thickness c. Brick lined Refractory insulation d. Three layers of refractory insulation e. Temperature Rating 1650 deg.C f. 42% alumina fire bricks Primary Chamber: a. 120Kw Burner  b. Dedicated independent fan system, damper controlled.  c. Thermostatic Sensor  d. Dimensions – 700mm x 700mm x g00mm e. Square Chamber with curved floor for liquid centralization Hot Hearth Chamber: a. 120Kw Burner b. Thermostatic Sensor  c. Minimum Temperature of 1100 deg.C as per WHO guidelines.  d. Two second retention time – Proven with CFD modeling. Steel Construction: a. constructed from 8mm & 1Omm steer plate  b. Painted two pack paint system, red with black flashing Control Panels: a. Door dimensions 700mm x 700mm b. Front mounted ash collection box. Control Panels: a. AiController b. Plug and play  c. Threezone monitoring of: i)Primary chamber               ii) Secondary chamber               iii) Hot hearth d. Digital display e. Burner on-off indication lights  f. Timer Chimney: a. Mild steel painted red b. Refractory insulated with 50mm of insulation. Unit Dimensions: 1840mm x 1 ‘1 50mm x 1950mm high. Safety: a. Burner door cut-off switches b. Fire valve fitted to fuel system  c. Maximum noise at 1m x g0 decibels  d. Exterior temperature 70 deg.C Max

Mobile Diesel Fired Incinerator in container

Mobile Diesel Fired  Incinerator in container,  supplied with the following specifications: complete with constant ventilation fans for extraction,  factory installed inside one 20ft ISO container complete with lighting, ventilation fan, fire security, 3 access doors, and a 1200 litre fuel tank complete with a piping.  Fully containerised mobile  waste management solution for medical, animal, and industrial waste applications. Installed in Container (ISO) : 20” or its nearest equivalent model “ Tender Technical Specification Destruction rate of 50kg/hr Hot Hearth Principle Refractory insulation: a. Silicon carbide floor b. Minimum 22mm insulation thickness c. Brick lined Refractory insulation d. Three layers of refractory insulation e. Temperature Rating 1650 deg.C f. 42% alumina fire bricks Primary Chamber: a. 120Kw Burner  b. Dedicated independent fan system, damper controlled.  c. Thermostatic Sensor  d. Dimensions – 700mm x 700mm x g00mm e. Square Chamber with curved floor for liquid centralization Hot Hearth Chamber: a. 120Kw Burner b. Thermostatic Sensor  c. Minimum Temperature of 1100 deg.C as per WHO guidelines.  d. Two second retention time – Proven with CFD modeling. Steel Construction: a. constructed from 8mm & 1Omm steer plate  b. Painted two pack paint system, red with black flashing Control Panels: a. Door dimensions 700mm x 700mm b. Front mounted ash collection box. Control Panels: a. AiController b. Plug and play  c. Threezone monitoring of: i)Primary chamber               ii) Secondary chamber               iii) Hot hearth d. Digital display e. Burner on-off indication lights  f. Timer Chimney: a. Mild steel painted red b. Refractory insulated with 50mm of insulation. Unit Dimensions: 1840mm x 1 ‘1 50mm x 1950mm high. Safety: a. Burner door cut-off switches b. Fire valve fitted to fuel system  c. Maximum noise at 1m x g0 decibels  d. Exterior temperature 70 deg.C Max

animal incinerator for sale

animal incinerator for sale (Hot sale model TS50, A360, A600 and A900) a.) Incinerator design for animal pet cremation. b.) Collect ash into pet cremation urns. c.) Pet in chamber individual. d.) Special design with movable platform. e.) Pet cremation is personal business more. f.) Pet cremation with regual pet size or weight g.) Pet…
Read more