Nanjing,China
+86-13813931455(WhatsApp)

Tag: English

HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.

MEDICAL WASTE INCINERATOR (50 C 60kg/hr)

Medical Waste Incinerator, 50 to 60 Kg/hr Support Health Sector Support Project Point of Installation (Hospitals) Moi Voi, Makindu, Maragua, Eldama Ravine and Isiolo District Hospitals 1.    General Description Supply, delivery, installation and commissioning of a medical waste incinerator suitable for disposal of Medical, General and Pathological waste in a safe and clean environment.  The unit shall consist of two chambers and operate on the principal of controlled air and temperature. The unit shall consist a particulate remover (scrubbers) as stipulated in waste management regulations, 2006 (Legal notice NO. 121 of 29th September, 2006).  The Unit shall be fully automatic and controlled by an automatic electronic controlled system except loading system which shall be manual.  The unit shall be capable of incinerating between 50 to 60 kg of solid medical waste per hour.  It shall be constructed from mild or aluminized steel lined with refractory material. Main unit Application For incineration, general and pathological Capacity   50 C 60 kg/h burn rate Type Two  combustion chambers type; primary  and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unit Operating time                Minimum 8 hours daily Operating temperature     From 850 0C to 1200 0C, Automatic controlled Residual Ash                    5 to 10%     3.2     Primary Chamber Construction Constructed from heavy duty mild or aluminized  steel Or equal and approved equivalent Insulation material            Refractory material lining similar or equal to calcium  Silicate and hot face combination of heavy duty brickwork Internal Construction        Fixed hearth type complete with gratings, concave bottom and charging door, lined with refractory material Charging Door                   Suitable for manual loading of wastes and with smooth  Dear seal equivalent of Ceramic seals with hinges. Door Lock                          Automatic, Electric type Ash removal door    Provided, for removing resultant bottom ash leftovers                              from the Primary chamber Gratings   Provided Loading Manual loading of waste Primary Burner                        Fully automatic, with fuel, temperature and speed controls with ignition system, flame detector, Air fan complete with safety features, flame failure,  Diesel fired fuel injector type and Flange mounted                                                                                                     Blower Provided. For supplying excess combustion air through the distribution system with speed control system Temperature Minimum exit 850 0C Observation port To be provided with protective glass type Construction   Constructed from heavy duty mild or aluminized steel or equal and approved equivalent Insulation Refractory material lining Combustion Temperatures        Above 850 0C, controlled electronically…
Read more

Incinerator Primary Combustion Chamber

HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial  trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed. Containerization is the most feasible and viable option in contrast to the construction of on-site facilities and housing structures,  eliminating the man power and costs involved. The system has the added benefit of total mobility (both local and international), and is ideal  for military and civil camps and remote locations where infrastructure is scarce. Incineration is the most obvious solution for total destruction of municipal waste, avoiding all the direct and indirect risks associated with  other disposal methods. Incineration perfectly fits into a trend of treating waste in a safe way, and if possible, at the same place where it was generated to avoid  cross-contamination risk and to keep waste treatment costs at acceptable level. WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel:  +86-25-8461 0201    Website: www.hiclover.com   Email: [email protected] Email: [email protected]  

Incinerator Primary Combustion Chamber

HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial  trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed. Containerization is the most feasible and viable option in contrast to the construction of on-site facilities and housing structures,  eliminating the man power and costs involved. The system has the added benefit of total mobility (both local and international), and is ideal  for military and civil camps and remote locations where infrastructure is scarce. Incineration is the most obvious solution for total destruction of municipal waste, avoiding all the direct and indirect risks associated with  other disposal methods. Incineration perfectly fits into a trend of treating waste in a safe way, and if possible, at the same place where it was generated to avoid  cross-contamination risk and to keep waste treatment costs at acceptable level. WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel:  +86-25-8461 0201    Website: www.hiclover.com   Email: [email protected] Email: [email protected]  

Refractory constructions incinerator

* Burning Rate                                                     (50-120kg/hour) * Minimum Operating Temperature                (850°ϲ(Primary combustion) * Maximum Operating Temperature               (1450°ϲ(Afterburner chamber) * Secondary Burning Capacity                         (Compulsory) * Density Insulation                                           (20mm high) * Refractory Casting                                          (Minimum 65mm) * Heavy duty refracting lining to withstand    (1500°ϲ) * Average burn out time: Maximum                (3.0 hours) * Fuel Type                                                          (Diesel) * Fuel Consumption in L/hr:                            (7.5 to 9) * Residence time in secondary chamber     (2 sec.) * Residue ash post 100kg                               (Max. 3.8kg) * Installation period                                            (Maximum 7days) Type : Refractory constructions Steel Structure 400+ Silica board + Fire Brick and Castable between Size : Outside – W 740 x L 1112 x H 790 / Inside – W 400 x L 800 x H 560 (mm) Fire load of Combustion volume : 0.18 m3 Fire table area : 0.32 m2 Material : SS400 x 6.0T, Silica Board, Fire Brick (SK-36), Castable (HACT-160) Temperature : 700 ~ 900 ℃ Residual gas combustion in secondary chambers : ≥ 2sec Input door size : W 200 x H 200 (mm) Ash door size : W 300 x H 400 (mm) Type : Refractory constructions Steel Structure 400+ Silica board + Fire Brick and Castable between Size : Outside – W 740 x L 1112 x H 745 / Inside – W 400 x L 800 x H 600 (mm)   Fire load of Combustion volume : 0.19 m3   Fire table area : 0.32 m2 Material :  SS400 x 6.0T, Silica Board 50T, Fire Brick (SK-36), Castable (HACT-160) Temperature : 1000 ~ 1100 ℃ WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat) Website: www.hiclover.com   Email: [email protected] Email: [email protected]   Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour…
Read more

England’s Garbage Producing Danish heat

“They save on having to bury the waste and we save on the consumption of natural gas,” he explained. READ MORE: Denmark pays for electricity Environmental protection agency Miljøstyrelsen explained that last year up to 200,000 tonnes of non-hazardous waste from England was incinerated in Denmark — almost six percentage of the total volume of…
Read more

50-100-150-200 Kgs per Hour Solid Waste Incinerator Model TS150 PLC 1570Liters Chamber

Waste Incinerator Model TS150 PLC, Overview This model is small-scale waste incineration equipment for small waste output.  Construction is dual/double combustion chamber with 02 sets oil burner, batch load  incineration equipment. Waste feed chamber is 1570Liters (1.57m3, TS150 PLC).  Primary & Secondary combustion chambers and smoke filter chamber.  Batch load on the bottom of chamber.…
Read more

hiclover 10kgs per hour incinerator

Smallest waste incinerator for small hospital  average 10kgs per hour.  with double(2) sets burner. Equipment Technical Specifications Model YD-10 Feed Capacity Average 20 kgs per feed Burning Rate Average 10 kgs per hour Burning Time per Feed 2 hours Voltage 220V Fuel Diesel oil Burner Italy Burner Feed Mode Manual Fuel consumption (Oil) 5.4-12.6 Kgs/Hour…
Read more

FFP2 Breathing mask machine

平面口罩机参数: Semi-Automatic Mask Machine l Power supply: 3.3KW mono phase l Mask Size: 175mm*80-100mm (two or three layers) l Nonwoven (GMS): 10-50g l Capacity: 120 to 150pcs/min l Dimension(L*W*H):3800mm*500mm*1400mm l Net Weight: about 1000kg   焊接机参数: Welding Machine l Capacity: 5 to 10pcs/min l Power supply: 8.5KW mono phase l Compressed Air connection: 0.5 to 0.7Mpa l Dimension(L*W*H): 900mm*650mm*1380mm l Net weight: approx. 50kg   KN95口罩机参数: N95 Mask Machine l Capacity:…
Read more

N95 Face Mask Machine Production Line on Sale Now! $250,000USD per set

N95 Face Mask Machine Production Line on Sale Now! $250,000USD per set N95 Face Mask Machine Production Line on Sale Now! $250,000USD per set l Dimension(L*W*H): 1037*855*1780 l Power Supply 15.3kw mono phase l Net Weight: approx.: 1500kg HICLOVER – Medical Environmental    WWW.HICLOVER.COM Waste Incinerators Medical Waste Incinerator Pet Animal Cremation Solid Waste Incinerator Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat) Website: www.hiclover.com   Email: [email protected]
Read more

Melt blown Production Line 400mm and 1600mm and ES Fiber Production Line and N95 Mask Machine and Disposable Mask Machine

1. N95 and Disposable Mask Machine   2. 400mm and 1600mm Melt blown Production Line 3. ES Fiber Production Line       N95 Face Mask Machine Production Line Melt blown Production Line   A.)Optional Capacity: 1600mm Efficiency: 95-97% FOB Term Price: USD per set Price Valid: 5days. Ave.60 Days ready for shipping. In stock…
Read more