Nanjing,China
+86-13813931455(WhatsApp)

Medical waste management in Nigeria

HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.

Medical waste management in Nigeria

Each incinerator shall be supplied with all necessary assembly/disassembly tools. Spare parts and consumables The proposed incinerator systems shall include all necessary spare parts, PPE, and consumables required for 2 years of operation. https://twitter.com/i/status/1578045332285698049
Incinerator Items/Model HICLOVER YD30(PLC) Burn Rate (Average) 30-50kg/hour(Medical Waste) 10-15kg/hour(Pet Animal Cremation) Feed Capacity(Average) 40kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 360L(0.36M3) Internal Dimensions 100x60x60cm Secondary Chamber 200L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.8Kw Burner Type Italy Brand Oil Consumption (kg/hour) 12 N.Gas Consumption (m3n/hour) 9.8–20 Temperature Monitor Yes Temperature Thermometer Corundum Probe Tube, 1400℃Rate. The supplier is to provide a proposed list of spare parts for the incinerators. Mandatory spare parts must include as a minimum. The forecasted feedstock loads, and daily loading rates are generally summarized as • Mixed general, clinical and incinerable hazardous wastes with a wide range of calorific values and densities. The majority of the wastes will be of a general municipal nature, with up to 15% by volume of medical wastes and up to 5% by volume of incinerable hazardous wastes. The content of the combustible matter will be above 60% and moisture content below 30%. The wastes will be crudely pre-mixed by selective loading from different waste streams prior to incinerator loading. • Wastes either small enough to fit within a 60 litre waste sack or broken up or shredded to less than 300mm in size. • Operation on a daytime shift basis, 5 days per week. • An 8 hour daily operating cycle of ash removal, pre-heat and burn with continuous loading if required. The automated burn completion and cool down cycle will take place overnight. • The incinerators shall be capable of using diesel fuel as a supplemental fuel while the associated management equipment shall be capable of using electricity as the primary power source • Also consider provision for meeting international emission standards. Able to handle an average waste production of 600kg/day “• Minimum load capacity: 100 kg https://www.tiktok.com/@wasteincinerators/video/7147354941236153646?is_from_webapp=1&sender_device=pc&web_id=7114539833770739242
• Maximum load capacity: 300 kg • Nominal burning rate: 70 – 120 kg/hr (= 560 – 960 kg per 8hour day) All incinerators shall meet the following emission and operating standards: • Combustion efficiency (C.E.) shall be at least 99.0% • The combustion efficiency shall be computed as follows: o C.E = (CO2 X 100) / (%CO2 +%CO) Suitably designed pollution control devices such as scrubbers, filters or electrostatic precipitators, shall be installed/retrofitted with the incinerator to achieve emission limits.”