Nanjing,China
+86-13813931455(WhatsApp)

Category: Waste Incinerators

HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.

Caso de proyecto

Análisis del mercado internacional de incineradores de residuos Fecha. 10 de junio de 2012 Palabra clave: pequeños incineradores incinerador de desechos médicos incinerador de cremación de animales de compañía fabricantes de incineradores El incinerador es un equipo de incineración, quema directamente los desechos mediante gas combustible o combustible oi. Como circunscripción diferente, incinerador se puede…
Read more

Ebola: Southport firm leading the fight in global health crisis

Sales and marketing manager Paul Niklas said they had more than a hundred orders from global organisations and aid agencies, including the United Nations and the Red Cross. He also said most of their workforce was dedicated to manufacturing the incinerators. The larger ones can burn up to 1,000kg of waste an hour, smaller ones…
Read more

Controlled air medical waste incinerator designed for incineration of bio-medical waste

Controlled air medical waste incinerator designed for incineration of bio-medical waste generated at a blood-processing center. The waste to be treated mainly includes bio-waste (i.e. bodily fluids), infectious and hazardous waste such as syringes, needles, and other medical waste (i.e. silicon rubbers, plastic, textiles, papers, packs, etc.) Operational Specs Physical Specs Combustion Chamber Volume (m3) 8.80m3 Burn Rate* up to 1,500kg per hour Average Fuel Consumption 65 kg per hour or more (7 diesel burners) Operational Temperature 850 – 1320°C Gas Retention in Secondary Chamber Large secondary chamber     Temperature Monitoring Yes     Average ash residue (%) 3%     Thermostatic Device Yes   1000l diesel flue tank Venture gas scrubber Hydraulic Ram Feeding System Diesel Powered Large Incinerator Minimum Specification Required Standards 1) Bidder or Manufacturer ISO 9001 Certified 2) Respecting international emission standards Electrical characteristics 3) A 230V, 60Hz single-phase electrical source. 4) Protections against over-voltage and over-current line conditions. 5) Compliance with applicable Ghanaian standards and regulations. Operational characteristics 6) Two-stage incineration with dual chamber combustion 7) Burn rate: 15 – 20 Kg/h 8) Capacity: not less than 130 L 9) Concentrations of most pollutants in stack gases below detection limits 10) Diesel fuel 11) Electronic system control 12) Easy to operate and minimal training 13) Any accessory or dedicated device necessary to the proper functioning and utilization of the equipment included PLEASE REFER TO BROCHURES ATTACHED FOR DETAILED SPECIFICATION

Supply of Inclinators for Interim Arrival Domestic Terminal Project

CMC Services for Inclinators for 3 years including all spares, consumables, Skilled Manpower, tools and tackles all complete. As per Scope attached as Annexure Design, Manufacture, Supply, delivery to site, installation, testing & commission of All weather proof Passenger Inclinators in accordance to the Scope and outline specifications mentioned in AnnexureSpesifikasi Incinerator 100kg/jam Spesifikasi dan Daftar Material Dimensi dan Power Capacity Nama Barang                                : INCINERATOR Type / Model                 : PWR-INC-KMN 10 Kapasitas                                 : 100kg/Jam (1 m3) Length                               : 288 cm   Width                                : 147 cm   Height                                    : 163 cm   Height of Chimney std            : 700 cm   TOTAL WEIGHT                   : 8000 kg  Panel – timer                 : Digital Included Auto Alarm Finishing                            : Hot endured paint  Fuel tank                           : 200 Liter  Covering Element from steel   : 3-8mm  Banyaknya Burner                   : 2 pcs   Banyaknya Blower               : 2 pcs  Max. Fuel consumption           : 15-30 Liter/Jam  Max. Elektric consumption   : 1100 Watt   Bahan bakar               : Kerosene / Diesel (solar)   Voltage                              : 220 V / 1 phase / 50 Hz   Material  1. PANEL CONTROL Type                       : Digital  Buatan                    : Local KAMINE ( Panel dan Incinerator satu Merek) Voltage                   : 220 V / 1 phase / 50 Hz   Safety operator       : Emergency Stop  System                    : Microkontroller  Pengoperasian         : Semi Automatic Temperatur control  : Digital Coupler Type Control panel : Manual dan automatic Tipe : Self Standing Type / Wall Mounted Type Material  : Mild steel Thermocontrol : 2 (Dua)  1200 ºC Set of timer : 0- 2 jam…
Read more

Controlled air medical waste incinerator designed for incineration of bio-medical waste

Controlled air medical waste incinerator designed for incineration of bio-medical waste generated at a blood-processing center. The waste to be treated mainly includes bio-waste (i.e. bodily fluids), infectious and hazardous waste such as syringes, needles, and other medical waste (i.e. silicon rubbers, plastic, textiles, papers, packs, etc. ) Operational Specs Physical Specs Combustion Chamber Volume (m3) 8.80m3 Burn Rate* up to 1,500kg per hour Average Fuel Consumption…
Read more

New Year Holiday 2015